Liquid Cooling Piping for AI Data Centers

Secondary-side loop networks, rack manifolds and CDU blocks engineered for facilities where a single drip can take a rack offline.

Stainless distribution manifold fabricated by Yijia Pipe

Application requirements

What This Application Demands

The pipework is specified by the failure modes it has to prevent, not by a catalogue part number.

Zero-leak tolerance

Coolant above live electronics leaves no acceptable leak rate. Custom assemblies are 100% helium leak tested before packing.

CDU and rack interfaces

Flow rates, connection types and isolation points must match the CDU vendor's and the rack integrator's drawings exactly.

Install speed

Prefabricated, labelled spools reduce hot work and pressure testing inside a live white space.

Long service life

Material, coolant chemistry and joint method are reviewed together so the loop stays tight through thermal cycling.

Where our piping fits

Components We Build for This Application

Complete loops are engineered to your P&ID or CAD package; these are the building blocks we fabricate in-house.

CDU modules and valve blocks

Distribution and collection blocks built to the CDU flow and isolation scheme.

Made to drawing

Rack-level manifolds

Multi-branch stainless headers with custom port count and pitch.

Made to drawing

Secondary loop piping networks

Prefabricated spools for IDC secondary-side distribution runs.

Made to drawing

Typical configuration

Specified Per Project

The table below describes the parameters we normally agree at engineering review. Nothing here is a fixed catalogue SKU - final values follow your drawing, coolant and acceptance criteria.

Project references on this site are de-identified at the owner's request. No client names, logos or identifiable site photography are published.

Indicative specification - confirmed at quotation
MaterialAISI 304 / 316L seamless stainless; coolant compatibility reviewed per project
InterfacesFlanged, pressed, threaded or welded to customer drawing
Testing100% helium leak test, hydraulic pressure test, dimensional check
DocumentationMTC 3.1, test records, packed for export with part identification
EngagementEngineering sample first, then batch production; MOQ and lead time quoted per drawing

Delivery

From Drawing to a Tested Assembly

One engineering team owns the loop from manufacturability review through to the leak-test record.

  1. Send the drawingP&ID, isometric or CAD package with flow rates, coolant type and interface points.
  2. Engineering reviewMaterial compatibility, wall thickness, joint method and routing checked, with a manufacturability proposal returned.
  3. FabricationIn-house cutting, bending, welding, passivation and dimensional inspection under one roof in Foshan.
  4. VerificationHelium leak test, hydraulic pressure test and MTC documentation before export packing.

Next step

Have a loop to build?

Send the drawing or a component list. Our engineers reply with manufacturability feedback, an indicative lead time and a quote.