Direct factory · Foshan, Guangdong, China|Custom liquid cooling systems for AI data centers
fantine.yijia@gmail.com | WhatsApp +86 159 7570 1348

Industries / Hospitals

Hygienic Fluid Transfer Piping for Hospital Facilities

Closed-loop and utility distribution for buildings that cannot schedule downtime and cannot compromise on cleanable internal surfaces.

Stainless distribution manifold fabricated by Yijia Pipe

Application requirements

What This Application Demands

The pipework is specified by the failure modes it has to prevent, not by a catalogue part number.

Service continuity

Redundant, isolatable runs and leak-tight joints keep critical building services online.

Cleanable internals

Smooth bore, full-penetration joints and passivated surfaces limit biofilm and sediment traps.

Quiet, flameless installation

Press-fit and prefabricated assemblies reduce hot work in occupied buildings.

Material declarations

Composition and mechanical values documented per batch with Mill Test Certificates.

Where our piping fits

Components We Build for This Application

Complete loops are engineered to your P&ID or CAD package; these are the building blocks we fabricate in-house.

Stainless press and weld fittings

Elbows, tees, reducers and flanges for fast, flameless assembly.

Made to drawing

Prefabricated pipe spools

Plant-room and riser runs built off-site to installation drawings.

Made to drawing

Distribution headers

Custom port-count manifolds for plant-room isolation and balancing.

Made to drawing

Typical configuration

Specified Per Project

The table below describes the parameters we normally agree at engineering review. Nothing here is a fixed catalogue SKU - final values follow your drawing, coolant and acceptance criteria.

NSF / WRAS material standards and DVGW W534 press-fitting tests are component-level standards. Yijia Pipe does not claim medical-device or healthcare-system certification.

Indicative specification - confirmed at quotation
MaterialAISI 304 / 316L seamless stainless tube
Size rangeDN15 - DN100 fittings in V and M press profiles
VerificationHydraulic pressure test; 100% helium leak test on custom liquid cooling assemblies
DocumentationEN 10204 3.1 MTC, dimensional inspection record

Delivery

From Drawing to a Tested Assembly

One engineering team owns the loop from manufacturability review through to the leak-test record.

  1. Send the drawingP&ID, isometric or CAD package with flow rates, coolant type and interface points.
  2. Engineering reviewMaterial compatibility, wall thickness, joint method and routing checked, with a manufacturability proposal returned.
  3. FabricationIn-house cutting, bending, welding, passivation and dimensional inspection under one roof in Foshan.
  4. VerificationHelium leak test, hydraulic pressure test and MTC documentation before export packing.

Next step

Have a loop to build?

Send the drawing or a component list. Our engineers reply with manufacturability feedback, an indicative lead time and a quote.